| Availability: | |
|---|---|
| Quantity: | |
Advanced Two-Stage Purification Process
Stage 1: High-Efficiency Chemical Clarification: As a premier Inclined Plate Chemical Lamella Clarifier, the system first employs chemical dosing (coagulants/flocculants) to destabilize suspended solids and colloids. The water then flows through multiple inclined plates, where the "shallow pool theory" takes effect, achieving sedimentation efficiency boosts of 50-60% and increasing treatment capacity by 3-5 times within the same footprint.
Stage 2: Integrated RO Polishing: The clarified supernatant from the first stage is directly fed into the integrated RO filtration unit. This semi-permeable membrane removes dissolved salts, micro-organisms, and residual impurities, producing water that meets the strictest standards for discharge or reuse.
Compact & Unified Skid-Mounted Design
The chemical preparation system, lamella settler, sludge hopper, high-pressure pumps, and RO membranes are all mounted on a single, robust skid. This drastically reduces the installation footprint, simplifies piping, and cuts down on civil engineering costs by over 40%.
Key Advantages for Demanding & Space-Constrained Sites
Turnkey Solution: From raw, turbid water to purified permeate, this Integrated Chemical Lamella Clarifier provides a complete treatment train in one package, streamlining procurement, installation, and operation.
Unmatched Final Water Quality: The combination of chemical precipitation and RO filtration ensures effluent quality that surpasses what any single technology can achieve, consistently meeting standards for turbidity, TDS, and heavy metals.
Automated Chemical Dosing & RO Protection: The integrated design allows for intelligent process control. The chemical pretreatment is optimized to protect the downstream RO membranes from fouling and scaling, significantly extending their service life and reducing operational costs.
Ideal for Remote or Complex Applications: Its plug-and-play nature and fully enclosed design make it perfect for regions with limited technical expertise, harsh climates, or sensitive environmental locations.
Wide Application Range
This system is the ideal choice for applications requiring guaranteed high-purity water:
Production of potable water from surface water sources (rivers, lakes).
Treatment and recycling of complex industrial wastewater to pure water standards.
Pre-treatment for high-purity water systems in pharmaceuticals, electronics, and power generation.
Product Parameters
| Model | Area (m²) | Plate size (mm) | Cake thickness (mm) | Filter chamber volume (L) | Plate Qty (pcs) | Filtration pressure (Mpa) | Motor Power (Kw) | Weight (Kg) | Dimensions L×W×H(mm) | Foundation Size(mm) | ||||||||||||||||||||
| L | B | D | H | |||||||||||||||||||||||||||
| X^Z100/1250-30UR | 100 | 1250×1250 | 30 | 1468 | 36 | ≥0.6 | 4.0 | 8307 | 5430×1900×1630 | 3970 | 850 | 1740 | 995 | |||||||||||||||||
| X^Z120/1250-30UR | 120 | 1746 | 43 | 9308 | 5880×1900×1630 | 4430 | ||||||||||||||||||||||||
| XZ150/1250-30UR | 150 | 2250 | 55 | 11000 | 6400×1900×1630 | 5210 | ||||||||||||||||||||||||
| X^Z160/1250-30UR | 160 | 2341 | 58 | 11492 | 6860×1900×1630 | 5400 | ||||||||||||||||||||||||
| XZ180/1250-30Uk | 180 | 2619 | 65 | 12494 | 7315×1900×1630 | 5860 | ||||||||||||||||||||||||
| X^Z200/1250-30U& | 200 | 2896 | 72 | 13504 | 7770×1900×1630 | 6310 | ||||||||||||||||||||||||
| X^Z220/1250-30Uk | 220 | 3214 | 80 | 14652 | 8290×1900×1630 | 6830 | ||||||||||||||||||||||||
| X^Z250/1250-30UR | 250 | 3650 | 91 | 16227 | 9010×1900×1630 | 7550 | ||||||||||||||||||||||||
| X^Z200/1500-35Uk | 200 | 1500×1500 | 35 | 3500 | 49 | ≥0.6 | 11 | 20030 | 6570×2200×1820 | 5250 | 1170 | 1990 | 1070 | |||||||||||||||||
| X^Z250/1500-35Uk | 250 | 4375 | 61 | 22978 | 7395×2200×1820 | 6090 | ||||||||||||||||||||||||
| X^Z300/1500-35Uk | 300 | 5250 | 74 | 26026 | 8300×2200×1820 | 6990 | ||||||||||||||||||||||||
| XMZ350/1500-35Uk | 350 | 6125 | 86 | 29220 | 9120×2200×1820 | 7840 | ||||||||||||||||||||||||
| X^Z400/1500-35Uk | 400 | 7000 | 99 | 32574 | 10050×2200×1820 | 8750 | ||||||||||||||||||||||||
| X^Z450/1500-35Uk | 450 | 7875 | 111 | 35586 | 10860×2200×1820 | 9590 | ||||||||||||||||||||||||
| X^Z500/1500-35Uk | 500 | 8750 | 123 | 38606 | 11730×2200×1820 | 10430 | ||||||||||||||||||||||||
| X^Z600/2000-40Uk | 600 | 2000×2000 | 40 | 12000 | 85 | ≥0.6 | 15 | 49000 | 11100×3000×2500 | 9200 | 1660 | 2000 | 1050 | |||||||||||||||||
| X^Z700/2000-40Uk | 700 | 14000 | 99 | 53000 | 12200×3000×2500 | 10300 | ||||||||||||||||||||||||
| X^Z800/2000-40Uk | 800 | 16000 | 113 | 57000 | 13350×3000×2500 | 1450 | ||||||||||||||||||||||||
| X^Z900/2000-40Uk | 900 | 18000 | 127 | 61000 | 14500×3000×2500 | 12600 | ||||||||||||||||||||||||
| X^Z1000/2000-40U& | 1000 | 20000 | 141 | 65000 | 15600×3000×2500 | 13830 | ||||||||||||||||||||||||
FAQ
Q: What is the typical installation and commissioning timeline?
A: As a pre-engineered Compact Lamella Clarifier, installation is swift—mainly involving placement, leveling, and connection. Commissioning can typically be completed within a few days to weeks.
Q: How skilled do operators need to be?
A: The system is designed for easy operation . We provide comprehensive manuals and training. Basic routine checks are sufficient for daily operation.
Q: Can it handle high-temperature or corrosive wastewater?
A: Yes. The Stainless Steel Lamella Clarifier variant offers excellent corrosion resistance. The inclined plates are made of chemically resistant polymers (PP/PVC) suitable for a wide pH range.
Q: What maintenance does it require?
A: Maintenance is minimal. The non-clogging design of the inclined plates (with a 60° angle) prevents sludge adhesion. Periodic sludge discharge and occasional visual inspection are typically sufficient.
Q: Do you offer overseas technical support?
A: Yes. We provide 24-hour online support , video technical guidance , and optional overseas installation and operation services.